Hangzhou Phase Change Technology Co., Ltd.
Main products:Phase change material (PCM laptop cool pad, PCM cool pillow, PCM cool mat, PCM cool panel, PCM cool vest), PCM cool vest, PCM cool panel)
Products
Contact Us
  • Contact Person : Ms. wang snow
  • Company Name : Hangzhou Phase Change Technology Co., Ltd.
  • Tel : 86-0571-86815016
  • Fax : 86-0571-82475076
  • Address : Zhejiang,Hangzhou,No.249,Zixia Village,Heshang Industrial Park,Heshang Town,Xiaoshan District
  • Country/Region : China
  • Zip : 310052

telecom battery cabinet with PCM panel battery cooling system

telecom battery cabinet with PCM panel battery cooling system
Product Detailed
1.size: 50*20*2cm, weight:2.2KG 2.indoor and outdoor cabinet 4.Latent heat 230KJ/KG 5.Self research and production, low price

Power Failure is very common in developing countries. Most BTS or Basic Telecom Shelters or Telecom Enclosures are equipped with electronic Equipments and Battery for emitting proper signal to the cell-phone users. Ac or Air conditioning is providec to keep it cool. When the power fails, the temperature inside the BTS or Basic Telecom Shelters start rising very rapidly due to heat generated by the equipments and also due to ambient conditions. Diesel Generators are provided to give back up. However they are largely depended on the alertness of the watchman cum operator at the site. The contractors often delay in sending diesel aggravating the problem. To minimize the dependence on generators, Back-up air-conditioning may be provided by phase change material. Latest™ 29T is used in India for giving back-up to Air-Conditions. 240kg of Latest™29T is generally used per BTS. 240kg*180 J/kg 43200 K Joules of backup.  This is equal to 43200/3600 = 12 KWH of energy ( Theoretical Value is 188KJ/Kg of PCM giving back-up of 12.5 KWH).

Our PH-29 PCM  panel to cool battery cabinet has been sucessfully applied in BTS telecom shelter. Our company supply PCM panels for CHINA UNICOM COMPANY.

The PCM panels are filled with PH-24/PH-29 PCM, either for indoor and outdoor cabinet, which freezes at below 20°C/25°C and melts at above 25°C/29°C. In freezing and melting process, the PCM panels absorb and release much amount of heat, and the two kinds of PCM phase change help a lot in decreasing temperature fluctuation in the battery cabinet.

PCM panel help keeping the temperature in the battery cabinet at a normal working temperature range, largely increase life expectancy for the battery cabinet.

Currently our company has PH-24PCM panel for indoor batter cabinet and PH-29 PCM panel for outdoor battery cabinet.

PH-24 AND PH-29 DATA SHEET

modelmelting point     (°C)latent heat(kj/kg)density(1.0×10^3kg/m^3)thermal conductivity(W/m.K)Variation of Volume   %subcooling degree   (°C)
PH-24242231.380.5610≤4
PH-29292261.390.5510≤4

PCM Panel specifications

Product

 item

Melt 

point 

(°C)

Crystalize

 point

 (°C)

Size

(mm)

Material

Latent heat(J/G)

Density(1.0x103kg/m3)

Thermal 

conductivity(W/m.K)

Remark

PH-29

29

25

500*200*20

Sodium sulfate, 

water,  HDPE

223

1.38

0.56

Outdoor 

cabinet

PH-24

24

20

500*200*20

Sodium sulfate,

 water, HDPE

226

1.39

0.55

Indoor 

cabinet

Advantages and Disadvantages of PCM panel between our company and other foreign countries

1. PCM latent heat: Our PCM has much larger latent heat than many other suppliers

2. Almost every PCM panel production process (PCM panel HDPE panel body production, PCM filling) is runned by ourselves, initial cost is largely lowerd. So, compared with other PCM panel suppliers, our PCM panel has much more obvious competitive price.

telecom battery cabinet with PCM panel battery cooling system

Verified Information This information is Verified by Bureau Veritas and validity period is 2012/11/01 --- 2013/11/01 All the information below may covers both Gold Supplier and its related companies , Their Relationship will be affirmed according to china laws and regulations , also it will be clearly display in the full report >> Production Capacity: Product line name Production Line Capacity Actual Units Produced(Previous Year)
Phase Change Material USD 4,720,000 per year USD 2,447,121
Export Market Distribution: Market Revenue(Previous Year) Total Revenue (%)
Eastern Asia USD 1,664,406 60.0
Western Europe USD 277,400 10.0
Domestic Market USD 832,803 30.0
Production Machinery: Machine Name Brand & Model No. Quantity Number of Year(s) Used Condition
Electric scissors FJM103 2 1.0 Acceptable
High frequency heat sealing machine No information 1 2.0 Acceptable
High frequency plastic sealing machine WANLI, GP10-H4 5 2.0 Acceptable
Plastic injection machine No information 1 2.0 Acceptable
Plastic cutting machine No information 1 2.0 Acceptable
Mixer machine No information 3 2.0 Acceptable
Low frequency heat sealing machine No information 10 1.0 Acceptable
Testing Machinery: Machine Name Brand & Model No. Quantity Number of Year(s) Used Condition
Metal detecting machine SY-6010 1 1.0 Acceptable
Production Flow: 1.Cutting 2.Material inspecting 3.Heat sealing 1 4.Filling 5.Heat sealing 2 6.Metal detecting 7.Final inspecting 8.Packing 9.Finish product Testing Report: Report Picture Report Name Report By Product Name & Model No. Report Date
MSDS SGS Phase change material 2011/05/19


Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.